Chloride Interferences in Wet Chemical Oxidation Measurements: Plausible Mechanisms and Implications

Yin Ting T Chiu1, Alyssa M Burns1, Simon Rosanka1

  • 1Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States.

ACS ES&T Water
|December 19, 2024
PubMed

Related Concept Videos

Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
655
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
165
Precipitation of Ions03:11

Precipitation of Ions

Predicting Precipitation
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
27.6K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
1.6K
Precipitation Titration Curve: Analysis01:21

Precipitation Titration Curve: Analysis

The precipitation titration curve demonstrates the change in concentration of one reactant with the volume of titrant added. During the titration of chloride ions with silver nitrate, the precipitation titration curve is divided into three regions: before, at, and after the equivalence point. Before the equivalence point, low redissolution of the sparingly soluble silver chloride precipitate gives a low silver ion concentration. However, in the second region, representing the equivalence point,...
1.0K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
382