Related Experiment Video
Updated: Jun 3, 2025

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Developing an Indocyanine Green Angiography Protocol for Predicting Flap Necrosis During Breast Reconstruction
Chu Luan Nguyen1,2,3, Nirmal Dayaratna3, Neshanth Easwaralingam1,2
1Department of Breast Surgery, Chris O'Brien Lifehouse, Camperdown, NSW, Australia.
Abstract:
BackgroundAlthough there is evidence that indocyanine green angiography (ICGA) can predict mastectomy skin flap necrosis during breast reconstruction, consensus on optimal protocol is lacking. This study aimed to evaluate various technical factors which can influence ICG fluorescence intensity and thus interpretation of angiograms.MethodSingle institution retrospective study (2015-2021) of immediate implant-based breast reconstructions postmastectomy using a standardized technique of ICGA, controlling for modifiable factors of ambient lighting, camera distance and ICG dose. "Time to perfusion" assessment was defined as elapsed time from ICG administration to perfusion assessment. Intraoperative "absolute" and "relative" IGCA perfusion values of mastectomy flaps, taken at different time points (30, 60 and 90 seconds), were correlated with postoperative flap outcomes.ResultsThere were 260 breast reconstructions with a 3.1% necrosis rate. ICGA perfusion values, when measured at 60 and 90 seconds, were significantly lower for cases that developed necrosis compared to cases that did not, and were both good predictors of necrosis (area under ROC curves, 0.84 and 0.85, respectively). Fluorescence intensity increased as "time to perfusion" assessment increased for flaps that did not develop necrosis (correlation coefficient, 0.9, P < 0.001). Perfusion value cut-off thresholds for predicting necrosis were higher for a longer "time to perfusion" assessment.ConclusionsA standardized ICGA protocol is recommended as ICG fluorescence intensity increased with "time to perfusion" assessment, and ≤30 seconds did not allow for accurate perfusion analysis. Using a perfusion recording of 60 or 90 seconds, and the corresponding perfusion value cut-off, may optimize reliability of perfusion assessments.
More Related Videos
05:14Author Spotlight: Overcoming Anti-VEGF Resistance Through Advanced Vascular Morphology Assessment in Choroidal Neovascularization
Published on: August 11, 2023
09:07The Superficial Inferior Epigastric Artery Axial Flap to Study Ischemic Preconditioning Effects in a Rat Model
Published on: January 27, 2023