Towards faster quality control of personal radiation protective equipment using CT scout or a dedicated biplanar
Pieter-Jan Kellens1, Sandrine Bayart1, Jan De Pooter2
1Medical Physics, Ghent University, Proeftuinstraat 86, 9000 Ghent, Belgium.
Abstract:
Quality control (QC) of personal radiation protective equipment (PRPE) is essential to detect tears and holes in the attenuating layers. Routinely, this QC is performed using fluoroscopy on a conventional X-ray table. However, such a QC procedure is laborious and time consuming. This study aims to establish faster PRPE QC using CT scout or a biplanar radiography device. A reproducible 0.25 mm lead-equivalent phantom of ten holes (diameter 10 mm - 1 mm) and two incisions (length 50 mm and 25 mm with a width of 0.63 mm) was created to assess the defect detection performance using fluoroscopy, CT scout (Siemens Somatom Definition Flash and GE Revolution) and a biplanar radiography device (EOS). Additionally, three pieces of PRPE were imaged on all modalities and compared in terms of speed and defect detection performance. Defect quantification was performed with an X-ray opaque grid, the modality's line tool and the built-in wand tool in ImageJ software. All modalities could visualize the smallest defects (1 mm). However, for the Siemens Flash, the smallest defect was only visible when the scout length was at most 50 cm. Fluoroscopy was the most time consuming (>1 min/piece). Both CT scout and the EOS allowed faster analysis (<10 s). The EOS system had the highest resolution of 5.19 pixels/mm for all set scan speeds. However, to image the reference pieces, a seamstress doll was needed. The wand tool was found to be the most accurate for defect estimation. Both the EOS and a CT scout allowed faster QC of PRPE with equivalent defect detection performance. However, specific positioning and scan length must be considered.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...