Related Experiment Video
Updated: May 7, 2025

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
Published on: July 28, 2013
Normalization Based on m/z Shift and Ion Intensity in SALDI-TOFMS Imaging of Samples with Non-Horizontal Surface
Riko Takata1, Kotaro Hashimoto1, Taichi Shimazaki1
1Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-City, Toyama 939-0398, Japan.
Abstract:
Matrix-assisted laser desorption/ionization (MALDI), surface-assisted laser desorption/ionization (SALDI), and time-of-flight mass spectrometry (TOFMS) imaging are used for visualizing the spatial distribution of analytes. Mass spectrometry (MS) imaging of a sample with a rough surface with a uniform distribution of an analyte does not provide uniform ion intensities in the image. A shift in the m/z value of the analyte ions is also observed. To resolve these issues, we proposed a normalization method for obtaining images based on the actual localization of an analyte. A platinum (Pt) film was used to facilitate ionization in SALDI. The Pt ions obtained from the film and copper(II)-phthalocyanine from a commercial blue pigment were used to evaluate the shift in the m/z values and ion intensities originating from the sample surface placed diagonally. The relationship between the shift in the m/z value and peak area in mass spectra was determined by analyzing the relationship between the shift and irradiated height position, as well as between the peak area and irradiated height position on the sample. The SALDI image can be obtained based on the actual location of the analyte to normalize the raw image data. Thus, the normalization of the ion intensities enables SALDI-MS imaging of samples with rough surfaces using high-resolution TOFMS. The proposed normalization method for SALDI-MS imaging enhances the accuracy and resolution of analyte localization on rough surfaces, benefiting applications in material science, biomedical research, forensic analysis, and industrial quality control.
More Related Videos
08:27Large-Scale Multi-Omics Genome-Wide Association Studies Mo-GWAS: Guidelines for Sample Preparation and Normalization
Published on: July 27, 2021
04:58Author Spotlight: Investigating the Role of Repetitive DNA Misregulation in Cancer Initiation and Immunotherapy Resistance
Published on: December 13, 2024
Related Concept Videos
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's...
Regression Toward the Mean
Data Validation
Key parameters for method validation include:
Normal Distribution
Applications of Normal Distribution
The heights of 15 to 18-year-old males from Chile from 1984 to 1985 followed a normal distribution. The mean height is 172.36...
Modeling in Therapy
Participant Modeling
Participant modeling involves therapists demonstrating calm and effective behaviors in...