Related Experiment Video
Updated: Jun 3, 2025

Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale Entropy
Published on: June 27, 2013
Comparison of Mean Values and Entropy in Accelerometry Time Series from Two Microtechnology Sensors Recorded at 100
Bruno Fernández-Valdés1, Ben Jones2,3,4,5,6, Sharief Hendricks2,3
1Research Group in Technology Applied to High Performance and Health, TecnoCampus, Department of Health Sciences, Universitat Pompeu Fabra, 08302 Barcelona, Spain.
Abstract:
Several microtechnology devices quantify the external load of team sports using Global Positioning Systems sampling at 5, 10, or 15 Hz. However, for short, explosive actions, such as collisions, these sample rates may be limiting. It is known that very high-frequency sampling is capable of capturing changes in actions over a short period of time. Therefore, the aim of this study was to compare the mean acceleration and entropy values obtained from 100 Hz and 1000 Hz tri-axial accelerometers in tackling actions performed by rugby players. A total of 11 elite adolescent male rugby league players (mean ± SD; age: 18.5 ± 0.5 years; height: 179.5 ± 5.0 cm; body mass: 88.3 ± 13.0 kg) participate in this study. Participants performed tackles (n = 200), which were recorded using two triaxial accelerometers sampling at 100 Hz and 1000 Hz, respectively. The devices were placed together inside the Lycra vests on the players' backs. The mean acceleration, sample entropy (SampEn), and approximate entropy (ApEn) were analyzed. In mean acceleration, the 1000 Hz accelerometer obtained greater values (p < 0.05). However, SampEn and ApEn were greater with the 100 Hz accelerometer (p < 0.05). A large relationship was observed between the two devices in all the parameters analyzed (R2 > 0.5; p < 0.0001). Sampling frequency can affect the quality of the data collected, and a higher sampling frequency potentially allows for the collection of more accurate motion data. A frequency of 1000 Hz may be suitable for recording short and explosive actions.
Related Concept Videos
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Mean From a Frequency Distribution
When such a data set is encountered,...
Discrete Fourier Transform
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Average Acceleration