Related Experiment Video
Updated: Apr 30, 2026

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
Strategies for generating synthetic computed tomography-like imaging from radiographs: A scoping review
Daniel De Wilde1, Olivier Zanier1, Raffaele Da Mutten1
1Machine Intelligence in Clinical Neuroscience & Microsurgical Neuroanatomy (MICN) Laboratory, Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background:
Advancements in tomographic medical imaging have revolutionized diagnostics and treatment monitoring by offering detailed 3D visualization of internal structures. Despite the significant value of computed tomography (CT), challenges such as high radiation dosage and cost barriers limit its accessibility, especially in low- and middle-income countries. Recognizing the potential of radiographic imaging in reconstructing CT images, this scoping review aims to explore the emerging field of synthesizing 3D CT-like images from 2D radiographs by examining the current methodologies.
Methods:
A scoping review was carried out following PRISMA-SR guidelines. Eligibility criteria for the articles included full-text articles published up to September 9, 2024, studying methodologies for the synthesis of 3D CT images from 2D biplanar or four-projection x-ray images. Eligible articles were sourced from PubMed MEDLINE, Embase, and arXiv.
Results:
76 studies were included. The majority (50.8 %, n = 30) were published between 2010 and 2020 (38.2 %, n = 29) and from 2020 onwards (36.8 %, n = 28), with European (40.8 %, n = 31), North American (26.3 %, n = 20), and Asian (32.9 %, n = 25) institutions being primary contributors. Anatomical regions varied, with 17.1 % (n = 13) of studies not using clinical data. Further, studies focused on the chest (25 %, n = 19), spine and vertebrae (17.1 %, n = 13), coronary arteries (10.5 %, n = 8), and cranial structures (10.5 %, n = 8), among other anatomical regions. Convolutional neural networks (CNN) (19.7 %, n = 15), generative adversarial networks (21.1 %, n = 16) and statistical shape models (15.8 %, n = 12) emerged as the most applied methodologies. A limited number of studies included explored the use of conditional diffusion models, iterative reconstruction algorithms, statistical shape models, and digital tomosynthesis.
Conclusion:
This scoping review summarizes current strategies and challenges in synthetic imaging generation. The development of 3D CT-like imaging from 2D radiographs could reduce radiation risk while simultaneously addressing financial and logistical obstacles that impede global access to CT imaging. Despite initial promising results, the field encounters challenges with varied methodologies and frequent lack of proper validation, requiring further research to define synthetic imaging's clinical role.
More Related Videos
09:37Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data
Published on: April 26, 2016
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography