Related Experiment Video
Updated: Jun 20, 2026

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Dynamic Reconstruction of the Nickel Ions' Behavior in Different Orthodontic Archwires Following Clinical Application
Mirela Georgieva1, George Petkov2, Valeri Petrov1
1Department of Orthodontics, Faculty of Dental Medicine, Medical University of Sofia, St. G. Sofiiski Blvd., 1431 Sofia, Bulgaria.
Abstract:
Rationale: Orthodontic archwires undergo chemical and structural changes in the complex intraoral environment. The present work aims to investigate the safe duration for intraoral use (related to the nickel release hypothesis) of different types of nickel-containing wires. By analyzing how the nickel content (NC) varies over time, we aim to provide practical recommendations for the optimal use of said archwires. Materials and Methods: Our analysis focuses on the following nickel-containing archwires: stainless steel, Ni-Ti superelastic, heat-activated NiTi and CuNiTi, and multi-force archwires. The studied archwires of each type were divided into three groups: group 1, as received; group 2, retrieved after intraoral exposure for less than 6 weeks; group 3, used for more than 8 weeks. To assess NC, measurements using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and laser-induced breakdown spectroscopy (LIBS) were performed in multiple regions of each wire. Statistical analysis of the measured values using one-way ANOVA and multiple group comparisons showed significant differences in nickel content between groups. The dynamic behavior of the statistical results for NC was then modeled using logistic regression and fitted with cubic splines. Conclusions: The proposed behavior model, with further refinement, could enable orthodontists to make informed, patient-specific decisions regarding the safe and effective use of orthodontic floss. The overall conclusion of the study is that due to stability, SS-CrNi, HA-Ni-Ti with Cu, and TriTaniumTM are suitable for long-term use, and due to higher nickel release, Ni-Ti-Superelastic, HA-Ni-Ti without Cu, and Bio-ActiveTM are better for short- to medium-term use.
Related Concept Videos
Bone Remodeling
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...