Radiation spectroscopy of irradiated VVER-1200 fuel with burnable Am-absorber: A computational approach
Sergey V Bedenko1, Gennady N Vlaskin2, Sergey D Polozkov3
1National Research Tomsk Polytechnic University, P.O. Box 634050, Tomsk, Russian Federation.
Abstract:
Safe storage of fresh and irradiated fuel is ensured by solving the problem of photon emission protection. The neutron component is usually not taken into account due to its low intensity. However, for the new VVER-1200 fuel, the neutron component consideration is a mandatory procedure for radiation safety. In this study, the radiation dose was calculated for a fuel consisting of UO2 with a heterogeneous distribution of Am2O2 microcapsules, and the (α, n) component of the neutron background was evaluated. A comparative analysis of radiation characteristics of fuel assemblies shows that there is a significant excess in both the neutron and the photon components of the fuel under study. The yield and dose of neutrons from Am-containing fuel exceed those of uranium-based fuels by a factor of two, and when calculating the dose, it is necessary to take into account the energy spectrum of (α, n) neutrons in Am2O2 microcapsules. The analysis of the impact of Am on the photon component indicates that ensuring radiation safety for both fresh and irradiated fuels necessitates addressing challenges associated with photon radiation protection. This study aims to establish comprehensive procedures and guidelines for the handling of novel fuel materials during both production and post-irradiation processes within the reactor environment.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Flame Photometry: Overview