Related Experiment Video
Updated: May 10, 2026

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Novel co-axial, disposable, low-cost 3D printed videolaryngoscopes for patients with COVID-19: a manikin study
Laura Gorman1, Andrew N Dickson1, Myles Monaghan1
1From the School of Medicine, University College Dublin (LG), I-Form Advanced Manufacturing Research Centre, University College Dublin (AND), Our Lady of Lourdes Hospital, Drogheda, Ireland (MM), I-Form Advanced Manufacturing Research Centre, University College Dublin (FV), The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital (AMNCH) & Rotunda Hospital (BM), I-Form Advanced Manufacturing Research Centre, University College Dublin (DPD), Rotunda Hospital Dublin & Mater Misericordiae University Hospital Dublin (CM), and School of Medicine, University College Dublin, Dublin, Ireland (JFXJ).
Background:
COVID-19 continues to present challenges to both patient management and the protection of the airway management team involved, in particular in resource-constrained low-income countries. Among the most concerning complications in affected patients is rapid hypoxemic respiratory failure requiring tracheal intubation and mechanical ventilation. Videolaryngoscopy without peri-intubation oxygenation is the recommended approach in COVID-19 patients. However, the absence of peri-intubation oxygenation during intubation attempts can lead to hypoxia, and result in life-threatening complications in already critically ill patients.
Objective:
To develop low-cost disposable 3D printed videolaryngoscope designs with integrated channels for oxygen, suction, WIFI-enabled camera and tracheal tube channels, as well as a flexible transparent barrier anchor to offer optional additional protection to the user and airway management team.
Design:
A manikin study.
Setting And Participants:
Three experienced consultant anaesthetists in the Mater Misericordiae University Hospital, Dublin, Ireland.
Main Outcome Measures:
To generate novel co-axial videolaryngoscopes that meet International Standards, ISO7376 : 2020 standards for anaesthetic and respiratory equipment (laryngoscopes for tracheal intubation), and to demonstrate successful tracheal intubation of a manikin trainer in a range of configurations ('easy' to 'difficult') in accordance with the Cormack-Lehane grading of laryngeal view.
Results:
Final design prototypes met the minimum criteria for strength and rigidity according to ISO7376 : 2020, including blade tip displacement under load (65 N and 150 N). Preliminary validation has demonstrated successful tracheal intubation of a manikin trainer in all configurations including 'difficult' (Cormack-Lehane Grade 3 view).
Conclusions:
This low-cost, rapid in-house manufacture could offer a mitigation of supply chain disruptions that can arise during global pandemics. Furthermore, it could offer a low-cost solution in low-income countries where there is an infection risk caused by re-using most current videolaryngoscopes requiring sterilisation before re-use, as well as limitations in the availability of personal protective equipment.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques

