Performance of Unmodified Mechanical Ventilators With 2% Hydrogen Gas Mixtures
Julia Garcia Mancebo1, Kristen Sack2, Richard Nguyen3
1Dr. Mancebo is affiliated with Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts; Division of Critical Care, Texas Children's Hospital, Houston, Texas; and Department of Pediatrics, Baylor College of Medicine, Houston, Texas.
Abstract:
Background: Molecular hydrogen (H2) is a breathable gas that has been shown to have anti-oxidative, anti-inflammatory, and anti-apoptotic properties that may positively impact ischemia-reperfusion injury. The provision of 2% H2 through unmodified mechanical ventilators may facilitate the clinical translation of H2 as a therapeutic in critical illness. The effect of 2% H2 on ventilator performance is unknown. Methods: Unmodified Maquet Servo-i, Maquet Servo-u, Dräger Evita Infinity V500, and Dräger Evita Babylog VN500 ventilators from clinical stock were tested in an experimental closed system using certified, premixed air and O2 containing 2% H2 gas. Wall air and O2 supply were used as control. Ventilator settings were varied across the spectrum of neonatal to adult settings. End points included (1) difference between set and delivered tidal volume (VT) (Douglas method), (2) difference between set versus delivered O2 concentration, (3) delivered H2 concentration (gas chromatography), and (4) ventilator pre-use check malfunction. Correlation between set and measured end points were quantified by linear regression analysis and bias by Bland-Altman analysis. Results: During H2 administration, the average bias in measured versus set VT was within ± 10% for all ventilators except for the Babylog VN500, which exhibited an average bias of -89.2% (95% CI -107.0 to -71.3). The average bias in measured FIO2 was within ± 10% of set for all ventilators. Except for the Babylog VN500, all ventilators passed the pre-use check. Conclusions: Unmodified Servo-i, Servo-u, and Evita V500 ventilators deliver 2% H2 mixtures with acceptable accuracy in VT and FIO2. The Babylog VN500, which uses hot-wire anometry and a higher set operating temperature, exhibits unacceptably inaccurate delivery of VT with H2 mixtures.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...