Related Experiment Video
Updated: May 27, 2025

Robotic Spleen-Preserving Distal Pancreatectomy: The Warshaw and Kimura Techniques
Published on: July 26, 2024
Robotic distal pancreatectomy using the hinotori™ surgical system: Differences in surgical techniques from the
Yuichiro Uchida1, Takeshi Takahara1, Takahisa Kawase1
1Department of Surgery, Fujita Health University, Japan.
Background:
The use of the hinotori™ Surgical System (hinotori) in distal pancreatectomy (DP) is new compared to the da Vinci™ Surgical System (DVSS). The hinotori is equipped with mechanisms distinct from those of DVSS, and comprehensive reports detailing the surgical techniques and outcomes associated with hinotori in DP (hinotori-DP) are lacking. This study aimed to compare the outcomes of DP using the hinotori and DVSS (Xi system), focusing on differences in settings and techniques between the two methods.
Methods:
This study retrospectively investigated consecutive patients who underwent robotic DP from April 2010 (the introduction of robotic DP at our institute) to July 2024. The analysis excluded patients who underwent spleen-preserving procedures or procedures performed using robotic platform other than hinotori or daVinci Xi. The hinotori-DP cases were compared with those performed using DVSS (DVSS-DP). The techniques used in hinotori-DP were examined in more detail.
Results:
A total of 75 robotic DP cases (11 with hinotori and 64 with DVSS) were analyzed in this study. Different port configurations and techniques, including a lesser curvature approach, were used in the hinotori-DP compared to DVSS-DP. The operation time was relatively shorter in the hinotori-DP group (299 vs. 366 min, p = 0.095), and the postoperative complication rates were comparable (pancreatic fistula: 27 % vs. 30 %, p = 0.871; Clavien-Dindo Grade ≥3a complications: 18 % vs. 19 %, p = 0.964) between the two groups.
Conclusion:
The hinotori-DP can be safely performed by focusing on the unique characteristics of the hinotori surgical system.