Related Experiment Video
Updated: May 25, 2025

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Measuring Minerals in Pseudocereals Using Inductively Coupled Plasma Optical Emission Spectrometry: What Is the
Ana C Nascimento1, Carla Motta1, Andreia Rego1
1Food and Nutrition Department, National Institute of Health Doutor Ricardo Jorge, 1649-016 Lisbon, Portugal.
Abstract:
Pseudocereals have gained attention due to their adaptability to different climates, high nutritional value, and suitability for gluten-free and plant-based diets. However, a challenge lies in the necessary adaptations in the diet pathways, mainly due to the lack of matrix-matching metrological tools. To address this problem, we developed a classification system to support laboratory decisions without shaped Proficiency Testing (PT) or Certified/Standard References Material. This system evaluates method performance through limit of detection (LOD), maximum uncertainty, and statistical comparison. For that matter, the mineral contents (Cu, Mn, Fe, Zn, Mg, P, Ca, K, and Na) of quinoa (Chenopodium quinoa), amaranth (Amaranthus caudatus), and buckwheat (Fagopyrum esculentum) were determined, using three different digestion methods, including dry-ashing, microwave, and graphite block acid digestion. A decision was reached concerning the optimal digestion method to be employed, with the results classified into three categories: (i) "rejected if results failed in two categories; (ii) "use with caution" if results were not satisfactory in one category; or (iii) "accepted", if the results passed in all the categories. The system efficacy was exemplified by the effectiveness of dry-ashing and graphite block acid digestion by comparison with microwave digestion. Neither dry-ashing nor graphite block acid digestion can be recommended as an alternative method to the microwave digestion method when all the prioritized nutrient minerals are understudied. Although the microwave method is preferable for multi-elemental analysis, it is possible to obtain, with caution, comparable results from all the digestion methods if a higher relative combined uncertainty is defined (target uncertainty < 11%) under the assumption that this is suitable for the study.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Instrumentation

