Related Experiment Video
Updated: May 24, 2025

Method to Measure Tone of Axial and Proximal Muscle
Published on: December 14, 2011
Nonlinear acceleration disturbance observer to reject transient peak disturbances for an inertial
Qihui Bian1, Qingqing Miao1, Zhiyong Yu1
1National Key Laboratory of Optical Field Manipulation Science and Technology, Chinese Academy of Sciences, Chengdu 610209, China; Key Laboratory of Optical Engineering, Chinese Academy of Sciences, Chengdu 610209, China; Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
A high-bandwidth nonlinear acceleration disturbance observer (NOADOB) is proposed to reject transient peak disturbances mainly arising from velocity commutation of an inertial stabilization-tracking platform (ISTP). The approach is essentially based on extracting acceleration peak signals and applying a saturation function. The observer structure employs acceleration measurements and combines velocity loop input and control quantity to acquire peak signals. Differing from the general disturbance observer, the extraction of acceleration peaks is used to quickly capture the change in error and effectively reduce the impact of signal noise for the observer implementation. To trade off the observer bandwidth and the system stability, a partial compensatory scheme of limiting the filter output with a nonlinear saturation function is adopted. The relationship between the saturation threshold and the filter bandwidth is analyzed for optimal balance. It is theoretically and experimentally proved the effectiveness of NOADOB in attenuating error peaks. Moreover, the proposal accelerates the dynamic response to peak disturbances, breaks through the constraint of accurate modeling, and improves disturbance rejection performance.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Relative Motion Analysis - Acceleration

