A Systematic Review of Needleless Connector Function and Occlusion Outcomes: Evidence Leading the Way

Nancy Moureau1, Lisa Gorski, Julie Flynn

  • 1Author Affiliations: PICC Excellence, Inc. Hartwell, Georgia (Dr Moureau and Ms Johnson); Griffith University, Brisbane, Queensland, Australia (Dr Moureau); Alliance for Vascular Access Teaching and Research (AVATAR Group), Griffith University, Brisbane, Queensland (Drs Moureau and Flynn); Ascension at Home, Milwaukee, Wisconsin (Ms Gorski); School of Nursing and Midwifery, University of Southern Queensland, Ipswich, Queensland, Australia (Dr Flynn); TridentCare, Horsham, Pennsylvania (Ms Johnson).

Abstract

Related Concept Videos

Ammeter01:11

Ammeter

An ammeter is a current measuring instrument. In the circuit, it is represented by the symbol A. The ammeter is placed in series with the device or component to measure the current. A series connection is used because objects in series have the same current passing through them. If a circuit has multiple resistors and the current needs to be measured in each resistor, the number of ammeters required depends on whether the circuit is in series or parallel.
When an ammeter is used to measure the...
Thevinin's Theorem01:15

Thevinin's Theorem

Thévenin's theorem plays a pivotal role in electrical circuit analysis, offering a solution to the challenges posed by variable loads within a circuit. In practical applications, it is common to encounter circuits where certain elements remain fixed while others fluctuate, often referred to as the "load." A typical household electrical outlet serves as a prime example of a variable load, as it can be connected to a variety of appliances, each with its own unique electrical characteristics.
Block Diagram Reduction01:22

Block Diagram Reduction

The process of deriving the transfer function of a control system often involves reducing its block diagram to a single block. This simplification can be achieved through a series of strategic operations, including relocating branch points and comparators. These operations preserve the overall function of the system while allowing for easier manipulation and combination of blocks.
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying: