Mats Wallin1, Magnus Hallback2, Hareem Iftikhar3
1Department of Physiology and Pharmacology, Karolinska Institute, Stockholm, Sweden.
Background:
Cardiac output and mixed venous oxygen saturation are key variables in monitoring adequate oxygen delivery and have typically been measured using pulmonary artery catheterisation. The capnodynamic method measures effective pulmonary blood flow utilising carbon dioxide kinetics in ventilated patients. Combined with breath-by-breath measurements of carbon dioxide elimination, a non-invasive approximation of mixed venous oxygen saturation can be calculated.
Methods:
This study primarily investigated the agreement between mixed venous oxygen saturation calculated using the capnodynamic method and blood gas analysis of mixed venous blood sampled via a pulmonary artery catheter in 47 haemodynamically stable postoperative cardiac patients. Both measurements were synchronised and performed during alveolar recruitment by stepwise changes to the level of positive end-expiratory pressure. Simultaneously, we studied the agreement between effective pulmonary blood flow and thermodilution cardiac output. The Bland-Altman method for repeated measurements and calculation of percentage error were used to examine agreement. Measurements before and after alveolar recruitment were analysed by a paired t test. The study hypothesis for agreement was a limit of difference of ten percentage points between mixed venous oxygen saturation using the capnodynamic algorithm vs. catheter blood gas analysis.
Results:
Capnodynamic calculation of mixed venous saturation compared to blood gas analysis showed a bias of -0.02 [95% CI - 0.96-0.91] % and limits of agreement at 8.8 [95% CI 7.7-10] % and - 8.9 [95% CI -10-- 7.8] %. The percentage error was < 20%. The effective pulmonary blood flow compared to thermodilution showed a bias of - 0.41 [95% CI - 0.55-- 0.28] l.min-1 and limits of agreement at 0.56 [95% CI 0.41-0.75] l.min-1 and - 1.38 [95% CI - 1.57--1.24] l.min-1. The percentage error was < 30%. Only effective pulmonary blood flow increased by 0.38 [95% CI 0.20-0.56] l.min-1 (p < 0.01) after alveolar recruitment.
Conclusions:
In this study, minimal bias and limits of agreement < 10% between mixed venous oxygen saturation calculated by the capnodynamic method and pulmonary arterial blood gas analysis confirmed the agreement hypothesis in stable postoperative patients. The effective pulmonary blood flow agreed with thermodilution cardiac output, while influenced by pulmonary shunt flow.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...