Related Experiment Video
Updated: May 23, 2025

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Percutaneous Coronary Treatment With Bioadaptor Implant vs Drug-Eluting Stent: 2-Year Outcomes From BIOADAPTOR RCT
Shigeru Saito1, Johan Bennett2, Holger M Nef3
1Heart Center, Iryohojin Tokushukai Shonan Kamakura General Hospital, Kamakura City, Japan.
The DynamX bioadaptor implant demonstrated superior outcomes compared to the Resolute Onyx stent, showing significantly lower rates of target lesion failure (TLF) and target vessel failure at two years in patients with de novo coronary lesions.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Biomaterials Science
Background:
- The sirolimus-eluting bioadaptor is a novel coronary implant designed to maintain vessel dynamics post-percutaneous coronary intervention.
- It aims to restore hemodynamic modulation, including pulsatility and vasomotion, after the polymer coating resorbs.
Purpose of the Study:
- To present the first randomized clinical trial data comparing the DynamX bioadaptor implant with the Resolute Onyx drug-eluting stent.
- To evaluate the 2-year clinical outcomes of the DynamX bioadaptor.
Main Methods:
- A multicenter, single-blind, 1:1 randomized clinical trial involving 34 hospitals across Japan, Europe, and New Zealand.
- The study included patients with de novo coronary lesions, with target lesion failure (TLF) at 12 months as the primary endpoint.
- Two-year outcomes are reported for the per-protocol population (n=440).
Main Results:
- The DynamX bioadaptor group showed significantly lower rates of TLF (1.8% vs 5.5%) and target vessel failure (1.8% vs 5.9%) at 2 years compared to the Resolute Onyx stent.
- Fewer revascularization events were observed in the bioadaptor group between 6 months and 2 years.
- No definite or probable device thrombosis was reported in the bioadaptor group versus 0.5% in the stent group.
Conclusions:
- The DynamX bioadaptor implant demonstrated superior efficacy compared to the contemporary Resolute Onyx drug-eluting stent at 2-year follow-up.
- Fewer target lesion failure events were observed in patients treated with the bioadaptor.
- This study provides the first 2-year outcomes comparing the bioadaptor to a drug-eluting stent.