Related Experiment Video
Updated: May 22, 2025

Glaucoma-inducing Procedure in an In Vivo Rat Model and Whole-mount Retina Preparation
Published on: March 12, 2016
Pattern of Long-Term Intraocular Pressure Variation Following Gonioscopy-Assisted Transluminal Trabeculotomy:
Bruno M Faria1,2,3, Diego T Dias4,5, Mariana A O Reis6
1Marco Rey Ophthalmology Institute.
PréCis:
Patients with clinically uncontrolled open angle glaucoma submitted to isolated gonioscopy-assisted transluminal trabeculotomy or combined with phacoemulsification not only achieved low mean IOPs, but also demonstrated stable IOP patterns during a 24-month follow-up.
Purpose:
To assess the impact of gonioscopy-assisted transluminal trabeculotomy (GATT) on long-term intraocular pressure (IOP) variation.
Patients And Methods:
An unicentric retrospective study including 169 consecutive patients who had undergone standalone GATT or combined with phacoemulsification (PHACOGATT) due to clinically uncontrolled open angle glaucoma, with at least 12 months of follow-up was conducted. Long-term mean IOP, long-term IOP peak, long-term IOP fluctuation, coefficient of variation, mean-positive IOP variation, sustained clinically significant positive IOP variation, and number of follow-up visits with IOP ≥15 mm Hg were investigated.
Results:
One hundred sixty-nine eyes from 169 patients were included (GATT group=101 patients; PHACOGATT group=68 patients). Mean long term IOP (12.0±1.8 vs. 11.2±2.0 mm Hg), mean long-term IOP peak (12.9±2.6 vs. 11.8±3.5 mm Hg), and mean coefficient of variation (0.07±0.08 vs. 0.05±0.09) were lower in the PHACOGATT group, while mean IOP fluctuation (1.0±3.7 vs. 1.2±1.8 mm Hg) was lower in the GATT group. In addition, the overall mean-positive IOP variation was 0.79±1.64 mm Hg. Finally, only 6.5% of the patients presented sustained clinically significant positive IOP variation and IOP was ≥15 mm Hg in 5.9% of the follow-up visits.
Conclusions:
Patients with clinically uncontrolled open angle glaucoma submitted to GATT or PHACOGATT achieved low mean IOPs and demonstrated stable IOP patterns. Our results provide additional evidence supporting GATT and PHACOGATT as viable options for the treatment of medically uncontrolled glaucoma patients requiring low and stable IOPs.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
10:10Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
Published on: February 15, 2022
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Angle Closure Glaucoma: Treatment