Abstract:
ObjectivesAortic valve repair by tricuspidization with leaflet extensions is utilized in the management of aortic valve disease in children and adolescents. The aim of this study is to evaluate the long-term outcomes following aortic valve tricuspidization using polytetrafluoroethylene (PTFE) leaflet extensions at a single center.MethodsWe conducted a retrospective single-center analysis of 50 patients who underwent aortic valvuloplasty by tricuspidization with PTFE leaflet extensions between 2008 and 2024.ResultsFifty patients (37/50, 74% female) underwent aortic valvuloplasty using PTFE. The median age was 13 (interquartile range [IQR]: 1.8-25) years. During the median follow-up duration of 8.5 years (IQR: 8 months-15.8 years), 18 patients required reoperation at a mean of 7.3 ± 4 years. The 15-year survival rate was 95.6% (95% confidence interval [CI], 88%-98.8%), and 2 late deaths occurred. The freedom from reoperation at 1, 5, and 12 years was 100% (95% CI, 100%-100%), 82.8% (95% CI, 66.6%-91.4%), and 44.2% (95% CI, 26.2%-61%), respectively. At discharge, the mean peak systolic aortic valve gradients (15 ± 10 mm Hg) were significantly lower than preoperative (72 ± 35 mm Hg) values (P < .001). Mean of left ventricular end-diastolic diameter/body surface area index decreased from 38 ± 13 mm preoperatively to 34.4 ± 10.5 mm postoperatively, then reduced to 32 ± 7 mm at the latest follow-up (P = .003). Aortic regurgitation improved in all patients, and none had more than mild aortic regurgitation at hospital discharge.ConclusionsAortic leaflet extension valvuloplasty using PTFE is effective, safe, with excellent survival and favorable long-term outcomes. It provides reliable palliation in patients with congenital aortic valve diseases until a more permanent replacement alternative is available.
More Related Videos
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Endocarditis III: Medical Management