Air artifact suppression in phase contrast micro-CT using conditional generative adversarial networks
Md Motiur Rahman Sagar1, Lorenzo D'Amico2, Elena Longo2
1Translational Molecular Imaging, Max-Plank-Institute for Multidisciplinary Sciences, Germany.
Abstract:
3D virtual histology of formalin-fixed and paraffin-embedded (FFPE) tissue by means of phase contrast micro-computed tomography (micro-CT) is an increasingly popular technique, as it allows the 3D architecture of the tissue to be addressed without the need of additional heavy ion based staining approaches. Therefore, it can be applied on archived standard FFPE tissue blocks. However, one of the major concerns of using phase contrast micro-CT in combination with FFPE tissue blocks is the trapped air within the tissue. While air inclusion within the FFPE tissue block does not strongly impact the workflow and quality of classical histology, it creates serious obstacles in 3D visualization of detailed morphology. In particular, the 3D analysis of structural features is challenging, due to a strong edge effect caused by the phase shift at the air-tissue/paraffin interface. Despite certain improvements in sample preparation to eliminate air inclusion, such as the use of negative pressure, it is not always possible to remove all trapped air, for example in soft tissues such as lung. Here, we present a novel workflow based on conditional generative adversarial networks (cGANs) to effectively replace these air artifact regions with generated tissue, which are influenced by the surrounding content. Our results show that this approach not only improves the visualization of the lung tissue but also eases the use of structural analysis on the air artifact-suppressed phase contrast micro-CT scans. In addition, we demonstrate the transferability of the generative model to FFPE specimens of porcine lung tissue.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...