Cryo-TEM structure of β-glucocerebrosidase in complex with its transporter LIMP-2

Jan Philipp Dobert1, Jan-Hannes Schäfer2, Thomas Dal Maso3,4

  • 1Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.

Nature Communications
|March 30, 2025
PubMed

Related Concept Videos

Glucose Transporters01:27

Glucose Transporters

Glucose transporters facilitate the transport of glucose across the cell membrane. In addition to glucose, some glucose transporters can also aid the movement of other hexoses such as fructose, mannose, and galactose.
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Membrane Asymmetry Regulating Transporters01:19

Membrane Asymmetry Regulating Transporters

Enzymes like flippase, floppase, and scramblase transfer phospholipids from one layer to another in the membrane, thereby affecting membrane asymmetry.
Flippase
Eukaryotic flippases are type-IV P-type ATPases or P4-ATPases belonging to P-type ATPase family proteins that are membrane-bound pumps involved in the ATP-mediated transport of ions and molecules across the membrane. Flippases flip specific phospholipids from the outer to the inner leaflet of a membrane. All P4-ATPases have one...
Clathrin Coated Vesicles01:12

Clathrin Coated Vesicles

Clathrin-coated vesicles use endocytosis to transport receptors and lysosomal hydrolases from the Golgi to the lysosome in the late secretory pathway. Clathrin-mediated endocytosis was the first described endocytic process, and Clathrin-coated vesicles remain one of the most well-studied transport vesicles. The molecular machinery that generates clathrin-coated vesicles comprises over 50 proteins that precisely coordinate vesicle formation. Cell surface receptors concentrated in indented sites...
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...