A hybrid demand-side policy for balanced economic emission in microgrid systems

Arvind R Singh1, Bishwajit Dey2, Srikant Misra3

  • 1Department of Electrical Engineering, School of Physics and Electronic Engineering, Hanjiang Normal University, Shiyan, China.

Iscience
|March 31, 2025
PubMed

Related Concept Videos

Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
246
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
97
Secondary Distribution01:25

Secondary Distribution

Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
74
The Y-to-Y Circuit01:19

The Y-to-Y Circuit

In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...
391
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
90
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
139