Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Phonocardiogram signal dataset paired with blood pressure measurements
Kasidit Kokkhunthod1, Wongsathon Pathonsuwan1, Talit Jumphoo1
1Institute of Research and Development, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand.
Abstract:
This dataset comprises phonocardiogram (PCG) signals, blood pressure measurements, and additional demographic collected from 78 participants under controlled conditions. The data were recorded using medical-grade digital stethoscope and automated blood pressure monitor to ensure precision and consistency. PCG signals were captured at the Pulmonic area (P), located at the second left intercostal space near the sternum, and segmented into 10-s intervals with 50 % overlap, enhancing signal processing and analysis capabilities. Blood pressure measurements include systolic and diastolic values, along with demographic data such as age, weight, height, and gender, providing comprehensive physiological data. The dataset is structured to support various applications, particularly the development of artificial intelligence models for non-invasive blood pressure prediction, leading to early hypertension screening and prevention. This resource enables researchers to explore the relationships between PCG, blood pressure values, and physical characteristics, facilitating advancements in blood pressure health monitoring and diagnostics.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pre-Procedural Guidelines for Assessing Blood Pressure