Related Experiment Video
Updated: May 7, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Directional Coherence Factor for Volumetric Ultrasound Imaging With Matrix Arrays
Abstract:
Matrix arrays with small apertures limit spatial and contrast resolutions of volumetric ultrasound imaging. Coherence-based beamformers are prevalent for sidelobe suppression and resolution improvement. While the spatial coherence of a matrix array is fundamentally a 2-D function, conventional coherence factor (CF) methods neglect the directional variation of an ${M} \times {N}$ matrix array when calculating volumetric coherence. We hereby propose a projection-based directional CF (DCF) to exploit the 2-D nature of volumetric coherence function. Instead of computing the coherent and incoherent summations across the entire 2-D aperture, DCF projects aperture data onto azimuthal, elevational, diagonal, and anti-diagonal directions and subsequently calculates the CFs for each direction separately. The orthogonal coherence pairs, i.e., azimuth and elevation, and diagonal and anti-diagonal, are multiplied to obtain DCFRC and DCFDiag, respectively. The Jaccard similarity of DCFRC and DCFDiag is used to derive the final DCF to weigh the reconstructed images. We evaluated the performance of DCF beamforming in point-target simulations, multipurpose phantom experiments, and in vivo muscle imaging and compared it to delay-and-sum (DAS) and CF beamformers. Our DCF achieved sidelobe reduction throughout the entire volume compared to conventional CF. Moreover, diagonal weighting significantly improved, on average, the azimuthal resolution by 41.3% versus DAS and 7.35% versus CF as well as the elevational resolution by 40.4% versus DAS and 38.7% versus CF. Our proposed DCF offers a practical solution for resolution and contrast enhancement of volumetric imaging in 2-D matrix array configurations.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography