Related Experiment Video
Updated: May 15, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Evaluating Somfit's pulse arterial tonometry for detection of obstructive sleep apnoea
Marcus McMahon1,2, Jeremy Goldin3, Elizabeth Susan Kealy4
1Department of Respiratory and Sleep Medicine, Epworth Hospital, Richmond, Victoria, Australia.
Abstract:
This study evaluates the diagnostic accuracy of Somfit against polysomnography (PSG) for detecting obstructive sleep apnoea (OSA). Somfit is a wearable home-sleep monitoring device attached to the forehead, combining pulse arterial tonometry, oximetry, and actigraphy with sleep staging, arousals, and total sleep time (TST) derived from frontal neurological signals. Ninety-two participants suspected of having OSA were assessed using Somfit and simultaneous overnight PSG recordings at three Australian sites. Each PSG study was manually scored by three independent scorers. The reported statistics include standard measures of agreement between Somfit's TST, Oxygen-Saturation Index (ODI), Apnoea-Hypopnea Index (AHI), and the average of those metrics from the three PSG scorers. The overall inter-scorer agreement was 76% (kappa = 0.772). TST, ODI, and AHI from Somfit were highly correlated with similar metrics from PSG (all r > 0.84, p < 0.001). Sensitivity, specificity, and accuracy were 90.5%, 75.0%, and 89.1% respectively, with a diagnostic odds ratio (DOR) of 28.5 for AHI ≥ 5. For AHI ≥ 15, sensitivity, specificity, and accuracy were 78.0%, 73.8%, and 76.1%, respectively, with a DOR of 9.99. For AHI ≥ 30, sensitivity, specificity, accuracy, and DOR were 72.4%, 90.5%, 84.8%, and 24.9, respectively. The area under the curve (AUC) at different PSG AHI cut-offs ranged between 0.86 and 0.93. Coupled with oximetry and EEG-based derivation of TST, Somfit's performance is comparable to PSG in detecting OSA severity.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sleep Apnea
The condition is more prevalent among...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

