Comparison of Thiel-fixed and fresh-frozen temporal bon biomechanics with dynamic synchrotron-based X-ray imaging
Margaux Schmeltz1, Aleksandra Ivanovic2, Christian M Schlepütz1
1Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland.
Background:
The Thiel embalming method offers lifelike tissue preservation, yet its suitability for biomechanical studies remains debated.
Methods:
Here, we investigated two human temporal bones, one Thiel-fixed and one fresh-frozen, using dynamic synchrotron-based X-ray imaging under acoustic stimulation.
Findings:
Both specimens exhibited a linear response at the umbo, but the Thiel-fixed specimen displayed discontinuity after the incudo-malleolar joint, suggesting ossicular chain stiffening. Our findings align well with previous studies indicating potential tissue degradation induced by Thiel-embalming.
Interpretation:
These observations question the use of Thiel-fixed human specimens for biomechanical measurements on the middle ear, especially using dynamic synchrotron-based X-ray imaging. They emphasize the need for further assessment of the impact of Thiel-embalming methods on tissue mechanics.