Related Experiment Video
Updated: May 13, 2025

Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in
Ipek Kucuk1,2, Selenay Sadak2,3, Selda Zengin Kurnalı4
1Department of Analytical Chemistry, Faculty of Pharmacy, Başkent University, 06790, Ankara, Türkiye.
Abstract:
Cinacalcet hydrochloride (CIN) is a calcium-sensing receptor agonist used to treat hypercalcemia in the parathyroid. The molecularly imprinted polymer (MIP)-based sensor (CIN@MIP/GCE) was electropolymerized using cyclic voltammetry (CV) of the functional monomer o-phenylenediamine (o-PD) with a template molecule CIN on a glassy carbon electrode (GCE). The optimum performance of the MIP-based electrode for CIN detection was obtained with parameters of a 1:7 monomer ratio, a 15-min removal time, ethanol as a removal solution, and a 15-min rebinding time. The surface characterization of the CIN@MIP/GCE sensor was conducted using atomic force microscopy (AFM) and scanning electron microscopy (SEM), while CV and electrochemical impedance spectroscopy (EIS) were employed for electrochemical characterization with [Fe(CN)6]3-/4- redox probe. AFM findings show that the MIP sensor with CIN-specific voids on the surface has a root-mean-square (RMS) value of 27.95, while the non-imprinted polymer (NIP) sensor without voids has a smoother surface formation and an RMS value of 21.30 nm. The analytical efficacy of the constructed sensor was assessed using differential pulse voltammetry (DPV). The limit of detection (LOD) was 0.17 × 10-12, with a linear range of 1.0 × 10-12-1.0 × 10-11 M. The reliability of the constructed sensor was determined using CIN detection in real samples as tablet dosage form and human serum, yielding recovery results of 100.19% and 101.82%, respectively. The selectivity investigation was performed against prevalent interference substances. The relative imprinting factor (IF) values of CIN impurities confirmed the selectivity of the CIN sensor.
More Related Videos
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
Related Concept Videos
Potentiometry: Membrane Electrodes
Amperometry: Overview