Conversion of disclosed lens power formula constants
Related Experiment Video
Updated: May 11, 2025

Author Spotlight: Advancing Understanding of Age-Related Lens Stiffness Changes
Published on: April 5, 2024
Achim Langenbucher1, Peter Hoffmann, Alan Cayless
1From the Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany (Langenbucher, Wendelstein); Augen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany (Hoffmann); School of Physical Sciences, The Open University, Milton Keynes, United Kingdom (Cayless); Department of Ophthalmology, Johannes Kepler University Linz, Linz, Austria (Wendelstein); Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany (Szentmáry); Department of Ophthalmology, Semmelweis-University, Budapest, Hungary (Szentmáry).
Purpose:
To present a concept for interconverting constants of disclosed lens power formulas and to simplify these conversions to linear prediction models for clinical use.
Setting:
Augen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.
Design:
Retrospective single-center case series.
Methods:
Analysis based on a dataset with biometric measurements of 19 472 eyes in a cataractous population performed with the IOLMaster 700. The formula constant conversion from formula A to B includes 2 steps: calculation of the lens power using formula A with variation of formula A constant and back calculation of the constant for formula B for all constant values of formula A using nonlinear iterative optimization techniques to minimize the sum of squared formula B prediction error.
Results:
Formula conversion was calculated for the SRK/T A-constant (A = 117 to 121), Hoffer Q (pACD = 4.2 to 6.8), Holladay 1 (SF 0.5 to 3.0), Haigis (a0 0.0 to 2.5 with a1/a2 = 0.4/0.1), and Castrop (C 0.15 to 0.50 with H/R = 0.0) formulas. As the conversions follow linear dependencies, linear regression models were fitted to simplify formula constant conversions in clinical routine.
Conclusions:
Conversions of formula constants could be used in cases where, for example, new lens models are launched with only the nominal SRK/T A-constant available or in situations where constants for some of the formulas are not available. Conversions to constant triplets for the Haigis or Castrop formula require additional nonlinear boundary conditions to take full advantage of formulas with multiple constants.
Related Concept Videos
Focusing of Light in the Eye
Power Expended by a Constant Force
Power Factor Correction
Complex Power
Complex power is defined as the multiplication of the voltage and the complex conjugate of the current. The magnitude of this power, known as apparent power, is measured in volt-amperes (VA). Notably, the angle of the complex power equates to the...
Power Factor
Design of Transmission Shafts

