Related Experiment Video
Updated: May 11, 2025

Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Role of a mobile/USB endoscope in dacryology
Hare Ram Ojha1, Neha Verma1, Arunima Gupta1
1Department of Orbit and Oculoplasty, Raj Eye Hospital and Post Graduate Institute of Medical Sciences, Gorakhpur, Uttar Pradesh, India.
None:
To establish the role of a mobile/Universal Serial Bus (USB) endoscope in dacryology. A prospective observational study was conducted at a tertiary ophthalmic institute. A mobile/USB endoscope comprising a 14 cm long camera probe, 5.5 mm in diameter, consisting of a 1.3 MP mini camera and six light-emitting diode adjustable lights, was used for performing nasal endoscopy and therapeutic/minor procedures. This study was divided into three parts: diagnostic, minor, and therapeutic procedures. For diagnostic purposes, nasal endoscopy was performed - preoperative (n = 31) and postoperative (n = 22) dacryocystorhinostomy (DCR) - to identify the six anatomical landmark structures of the nose and patency of the ostium. For a minor procedure, retrieval of the retracted silicone intubation tube (n = 3) was attempted using this endoscope. For therapeutic purposes, endoscope-assisted probing in congenital nasolacrimal duct obstruction (CNLDO) patients (n = 6) and endoscope-assisted lacrimal intubation were attempted in cases of failed DCR (n = 7). Diagnostic endoscopy performed in the outpatient department (OPD) and operating room (OR) in preoperative and postoperative DCR patients was almost 80% (n = 25) and 90% (n = 20) successful, respectively. In the remaining patients, owing to deviated nasal septum (DNS) and hypertrophied turbinates, the endoscopy was partially successful or unsuccessful. The minor procedure performed in the OPD group was 100% (n = 3) successful. The therapeutic procedures performed in OR endoscope-assisted probing in CNLDO and endoscope-assisted lacrimal intubation in failed DCR were ~ 33% (n = 2) and ~ 15% (n = 1) successful, respectively. The USB endoscope is more economical, portable, and easy to handle; hence, it is a more convenient alternative to the standard nasal endoscope for diagnostic purposes in pre- and postoperative cases of DCR and is very useful for office/minor procedures; however, its use is limited for therapeutic purposes.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:

