Related Experiment Video
Updated: May 11, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Prediction of Prosthetic Heart Valve Interaction During Transcatheter Double-Valve Replacement Using a Bench Model
Vasu Nandhakumar1, Aashish Chopra1, Vignesh Gomathinayagam1
1Department of Cardiology, Institute of Cardio-Vascular Diseases, The Madras Medical Mission Hospital, Chennai, India.
Abstract:
Transcatheter aortic valve replacement in the presence of a preexisting bioprosthetic mitral valve can lead to significant interaction of the valves. Simultaneous transcatheter aortic valve and mitral valve deployment using balloon-expandable systems further complicates the interaction. We describe preprocedural computed tomography planning using novel parameters and bench tests to predict these interactions and their clinical significance. On the basis of the available anecdotal evidence, we propose a new classification system for the various types of interactions.