Clinical Outcomes, Healthcare Utilization, and Cost Following Implementation of a High-Sensitivity Cardiac Troponin
Indu Poornima1, Teigan Dwyer2, Tyson Barrett2
1Allegheny Health Network, Pittsburgh, Pennsylvania, USA.
Introduction:
High-sensitivity troponin (Hs-trop) protocols have been developed for the cardiac evaluation of chest pain patients presenting to emergency departments (ED), but uptake has been suboptimal.
Methods:
This retrospective study sought to evaluate the effects of an Hs-trop protocol (Roche Gen-5 troponin assay) implementation on patient outcomes, healthcare utilization, and costs. Patients presenting to EDs with chest pain following implementation of an Hs-trop protocol (POST) were compared to control patients presenting in the year prior (PRE). Study endpoints included troponin elevations, cardiac diagnostic testing, and ED disposition. Among patients discharged directly from the ED, 30- and 90-day death, new myocardial infarction (MI), ED returns, and hospital admissions were compared. In a subset with insurance data, post-discharge healthcare costs and utilization were compared.
Results:
Among 15 015 patients meeting study criteria, there were no differences in MI diagnoses POST versus PRE, but myocardial injury without MI was more frequent POST (aOR = 9.03; 95% CI: 7.44, 10.96). Noninvasive cardiac testing at the index ED encounter was less frequent POST (aOR = 0.72; 0.67, 0.78), with no difference for invasive angiography. Among patients directly discharged from the ED, no differences were observed for death, but POST patients had fewer ED returns (aOR = 0.70; 0.59, 0.83) and hospital admissions (aOR = 0.62; 0.45, 0.85) within 30 days. Overall healthcare utilization was 8.4% lower in the POST group (p < 0.001) but costs were not different.
Conclusions:
Following implementation of an Hs-trop protocol, decreases were observed in noninvasive cardiac testing, and ED returns and hospital admissions within 90 days of discharge, without compromising outcomes. Overall healthcare utilization declined.
More Related Videos
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Errors occurring during blood pressure monitoring
Several factors...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes