Related Experiment Video
Updated: May 12, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Explosives Analysis Using Thin-Layer Chromatography-Quantum Cascade Laser Spectroscopy
John R Castro-Suarez1,2, Luis A Pérez-Almodóvar1, Doris M Laguer-Martínez1
1Center for Chemical Sensors and Chemical Imaging and Surface Analysis Center, Department of Chemistry, University of Puerto Rico-Mayagüez, Mayagüez, PR 00681, USA.
Abstract:
A new hyphenated technique using thin-layer chromatography (TLC) to separate analytes in mixtures, coupled with mid-infrared (MIR) laser spectroscopy for identification and quantification, is presented. The method, which provides a means for rapid screening of analytes that is practical, low-cost, fast, robust, and reproducible, was tested using nitroaromatic and aliphatic nitro high explosives (HEs) as target analytes. HEs are anthropogenic contaminants containing an -NO2 group. For validation of the new technique, a direct comparison of the 2,4,6-trinitrotoluene (TNT) spectrum, obtained by attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy coupled with TLC, was carried out. The MIR laser spectroscopy-based method was evaluated by calculating the analytical figures of merit regarding the calibration curves' linearity and the method's sensitivity and precision. The TNT spectrum obtained by the MIR laser method showed two prominent and characteristic bands of the explosive at approximately 1350 cm-1 and 1550 cm-1 compared to the spectrum acquired by ATR-FTIR. The detection limit calculated for TNT was 84 ng, while the quantification limit was 252 ng. Multivariate analysis was used to evaluate the spectroscopic data to identify sources of variation and determine their relation. Partial least squares (PLS) regression analysis and PLS combined with discriminant analysis (PLS-DA) were used for quantification and classification. The new technique, TLC-QCL, is amenable to a smaller footprint with further developments in MIR laser technology, making it portable for fieldwork.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Flame Photometry: Lab
High-Performance Liquid Chromatography: Types of Detectors
Flame Photometry: Overview

