Related Experiment Video
Updated: May 21, 2025

Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry
Published on: September 3, 2010
Three-Layer Electrospray Constructing Charged Microdroplets for Online Derivatization and Position Identification of
Yuan Cao1,2, Chunlin Yue1,2, Jinqi Yang1,2
1Beijing National Laboratory for Molecular Sciences, CAS Research/Education Center for Excellence in Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Beijing Mass Spectrum Center, Institute of Chemistry Chinese Academy of Sciences, Beijing 100190, China.
Abstract:
Numerous studies have demonstrated that charged microdroplets can significantly accelerate chemical reactions. In this work, we developed a novel three-layer electrospray ionization source (TL-ESI). This source generated charged microdroplets capable of facilitating the rapid epoxidation of unsaturated lipid C═C bonds with the derivatization reagent 3-chloroperbenzoic acid (m-CPBA) in an online process, achieving a conversion rate of up to 92.8%─a performance not achievable with conventional electrospray ionization source (ESI). Compared to conventional ESI, the TL-ESI effectively compartmentalized reactants, enabled precise control over the reaction process, and supported rapid online derivatization of lipid C═C bonds with m-CPBA. When integrated with tandem mass spectrometry (MS/MS), this source further enabled the localization of lipid C═C bond positions. The TL-ESI is characterized by its simplicity in design, ease of operation, and seamless integration with mass spectrometry (MS). These advantages make it an efficient and practical tool for locating C═C bond positions in unsaturated lipids, even within complex sample matrices. Additionally, this work highlights the potential of the TL-ESI as an innovative platform for accelerating chemical reactions via charged microdroplets, offering a valuable addition to the toolbox of modern analytical chemistry.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...