The Association between opportunistic DECT-derived bone values and vertebral fracture status
Philipp Reschke1, Vitali Koch1, Christof M Sommer2
1Goethe University Frankfurt, University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main, Germany.
Introduction:
Osteoporosis is a major cause of spinal insufficiency fractures but often remains underdiagnosed. Dual-energy CT (DECT) enables reliable assessment of bone mineral density (BMD), but its limited accessibility highlights the need for alternative metrics. This study investigates the association between vertebral fracture status, DECT-derived BMD and alternative bone quality assessments, including Hounsfield Unit (HU)-based assessment and cortical thickness ratio.
Methods:
A total of 180 patients who underwent non-contrast DECT of the spine between January 2016 and December 2021 were retrospectively analyzed. All imaged vertebrae were assessed for acute insufficiency fractures. DECT-based BMD was assessed using a dedicated postprocessing software that applies material decomposition and compared with HU-based assessment and cortical thickness ratio. Statistical analysis included correlation analysis, logistic regression adjusted for age and sex, ROC and PR curve analyses.
Results:
Among 180 patients (97 females, median age of 65 years), 126 subjects (70 %) were confirmed to have insufficiency fractures. Patients with fractures had significantly lower values for DECT-based BMD (98.3 vs. 123.7 mg/cm3, p < 0.001), trabecular HU (93.5 vs. 159.5 HU, p < 0.001), and cortical thickness ratio (1.065 vs. 1.05, p < 0.001). Cortical HU showed no significant difference between patients with and without fractures (p = 0.35). DECT-based BMD provided the highest diagnostic accuracy for detecting insufficiency fractures, yielding an AUC of 0.8 for the ROC curve and an AUC of 0.9 for the PR curve. HU-based measurements (trabecular HU: Spearman ρ = 0.17; cortical HU: ρ = 0.2) and the cortical thickness ratio (ρ = -0.01) demonstrated only weak correlations with the reference standard, DECT-derived BMD.
Conclusion:
DECT-based BMD demonstrated the highest diagnostic accuracy for insufficiency fractures. HU-based assessments and cortical thickness ratio showed only weak correlations with DECT-based BMD, limiting their reliability as alternatives.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...


