A novel dose calculation system implemented in image domain
Related Experiment Video
Updated: May 5, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Jiawei Fan1,2,3,4, Xiaoling Zhu1,2,3,4, Jiazhou Wang1,2,3,4
1Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.
Purpose:
Modern intensity-modulated radiotherapy, aiming to deliver an accurate dose to the planning target volume while protecting the surrounding organs at risk, is regarded as the indispensable treatment for cancer in the clinic. An accurate and efficient dose calculation algorithm is essential to support and accelerate the treatment plan optimization process.
Method:
To improve the effectiveness of the dose calculation, deep learning methods are widely adopted to compute dose distributions from several variables mimicking the physical features required for dose calculation. However, these methods employed similar concepts and neural network inputs, and had only limited improvements to traditional dose calculation methods. In this work, we propose a new computing process, named DeepBEVdose, which is essentially distinct to the previous deep learning-based dose calculation methods. We present a novel image-domain dose calculation algorithm to automatically compute dose distributions from the computer tomography images and radiation field fluence maps. Specifically, a novel beam's eye view calculation scheme is introduced to substitute the traditional trivial ray-tracing procedure that cannot be removed in the previously published dose calculation system. Under this new calculation scheme, a generic two-dimensional convolutional neural network with minimal input requirements is sufficient to perform accurate dose calculation.
Results:
We demonstrate the feasibility of this approach with datasets acquired from multi-institutions with two different tumor sites (nasopharynx and lung). The average pixel-wise difference between the ground truth and the predicted results across all testing cases (both internal and external) is within 2%. The average 3D gamma passing rate is above 95% for all testing cases.
Conclusions:
We have developed a novel deep learning framework that effectively maps radiation fluences to dose distributions. The high accuracy and efficiency of the proposed approach indicate its potential for use in online adaptive plan optimization.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dosage Regimen Designs: Nomograms and Tabulations
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses