Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study
Raj Kumar Panta1, Zhye Yin2, Fredrik Grönberg2
1Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA.
Purpose:
This study investigates the imaging performance of a deep silicon-based photon-counting CT (Si-PCCT) in quantifying iodine contrast through a virtual imaging trial (VIT).
Methods:
We developed a VIT framework using Si-PCCT simulator and benchmarked it against a prototype using an ACR phantom for assessing spatial resolution and noise characteristics, and a geometric phantom for iodine quantification. We imaged geometrical phantoms (20 - 40 cm) with iodine concentrations ranging from 1 to 19.7 mg/ml and XCAT human models with iodine contrast at BMI of 19 to 38 kg/m2 across different radiation dose levels (13.9, 27.8, and 41.7 mGy of CTDIvol). We performed material decomposition, reconstructed iodine CT images, and evaluated iodine quantification accuracy.
Results:
The Si-PCCT simulator closely matched with the prototype, with differences within 3 % in MTF (f50 and f10) and 3.7 % (fpeak) in NNPS, and Root-Mean-Square Error of 0.12 mg/ml in iodine quantification. The mean absolute errors (MAE) between the estimated and ground-truth iodine concentration were 0.10, 0.25, and 1.80 mg/ml for 20, 30, and 40 cm phantoms, and 0.31, 0.37, and 0.70 mg/ml for XCAT human models with BMIs of 19, 28, and 38 kg/m2, respectively. Similarly, the MAEs were 0.88, 0.45, and 0.31 mg/ml for the geometrical phantoms, and 0.66, 0.5, and 0.46 mg/ml for human models at CTDIvol of 13.9, 27.8, and 41.7 mGy respectively. These results demonstrate accurate iodine quantification performance, influenced by object size and radiation dose.
Conclusion:
This study shows the promising clinical utility of Si-PCCT for accurate iodine quantification under clinically relevant imaging conditions.
More Related Videos
18:40Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography