A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Real-time estimations of blood glucose concentrations from sweat measurements using the local density random walk
Xiaoyu Yin1, Elisabetta Peri2, Eduard Pelssers3
1Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven , Noord-Brabant, Netherlands. x.yin@tue.nl.
Abstract:
Sweat provides a non-invasive alternative to blood draws, enabling glucose-concentration monitoring for both healthy individuals and diabetic patients. In our previous work, we demonstrated a strategy that accurately estimates blood glucose concentrations from sweat measurements. However, this method involves time-consuming simulations using a biophysical model, limiting its application to offline use. The goal of this study is to propose an approach that increases computational efficiency, thereby facilitating real-time estimation of blood glucose concentrations using sweat-sensing technology. To this end, we propose replacing the original biophysical model with the Local Density Random Walk (LDRW) model. This is justified because both models describe the pharmacokinetics of glucose transport through a convective-diffusion process. The performance of the LDRW model and the original biophysical model are compared in terms of estimation accuracy, computational efficiency, and model complexity, using seven datasets from the literature. The estimation of blood glucose concentrations using the LDRW model closely approximates that of the original model, with a root mean square difference of just 0.04 mmol/L between the two models' estimates. Remarkably, the LDRW model significantly reduces the average computational time to 2.6 s per data point, representing only 0.7% of the time required by the original method. Furthermore, the LDRW model demonstrates a smaller corrected Akaike Information Criterion value than the original method, indicating an improved balance between goodness of fit and model complexity. The proposed novel approach paves the way for the clinical adoption of sweat-sensing technology for non-invasive, real-time monitoring of diabetes.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure