Related Experiment Video
Updated: Sep 19, 2025

Bloodless Laparoscopic Partial Splenectomy Assisted by Bipolar Radiofrequency Excision Hemostatic Device
Published on: November 4, 2022
Robotic assisted splenectomy after failure of splenic angioembolization in blunt abdominal trauma
Zach Rollins1, Deki Tsering1, Anthony Mark2
1Department of Surgery, Virginia Commonwealth University, Richmond, VA, United States of America.
Traumatic blunt splenic injury in the hemodynamically stable patient is initially managed with a nonoperative strategy that may include angioembolization. If patients continue to have ongoing signs of bleeding after angioembolization, definitive management is surgical splenectomy. We report the case of a patient with a grade IV blunt splenic injury who had ongoing bleeding after angioembolization and was taken for diagnostic robotic surgery. An isolated splenic injury was identified and the patient was treated with robotic splenectomy. On one month follow up the patient was noted to be doing well with minimal pain. To our knowledge, this is the first report of robotic splenectomy after failed non-operative manage in the setting of trauma. This case shows the potential value of robotic surgery to apply the benefits of minimally invasive surgery in hemodynamically stable patients who fail non-operative management after traumatic splenic injury.
Traumatic blunt splenic injury in the hemodynamically stable patient is initially managed with a nonoperative strategy that may include angioembolization. If patients continue to have ongoing signs of bleeding after angioembolization, definitive management is surgical splenectomy. We report the case of a patient with a grade IV blunt splenic injury who had ongoing bleeding after angioembolization and was taken for diagnostic robotic surgery. An isolated splenic injury was identified and the patient was treated with robotic splenectomy. On one month follow up the patient was noted to be doing well with minimal pain. To our knowledge, this is the first report of robotic splenectomy after failed non-operative manage in the setting of trauma. This case shows the potential value of robotic surgery to apply the benefits of minimally invasive surgery in hemodynamically stable patients who fail non-operative management after traumatic splenic injury.
More Related Videos
12:34Robot-Assisted Radical Antegrade Modular Pancreatosplenectomy Including Resection and Reconstruction of the Spleno-Mesenteric Junction
Published on: January 3, 2020
02:09Application of Laparoscopic Partial Splenectomy with Total Blood Flow Occlusion in Benign Splenic Lesions
Published on: December 20, 2024