Related Experiment Video
Updated: Sep 19, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Retentive Strength of Stainless-Steel Crown with Three Different Luting Cements - An In vitro Study
Amit Vilas Tandulkar1, Lumbini Pathivada1, Nishita Garg2
1Department of Paediatric and Preventive Dentistry, Rungta College of Dental Sciences and Research, Bhilai, Chhattisgarh, India.
Background:
Although stainless-steel crowns (SSCs) have a high clinical success rate, a key reason for its clinical failure is loss of crown due to cementation failure. Therefore, the choice of cementation material has an important effect on SSC retention.
Aim:
To evaluate the retention strength of SSCs luted on primary molars with glass ionomer cement (GIC), resin-modified glass ionomer cement (RMGIC) and resin-based cement.
Materials And Methods:
A total of 45 freshly extracted human primary molars were prepared to receive SSCs and randomly divided into three equal groups, to receive the different luting cements: conventional glass ionomer, resin-modified glass ionomer and resin luting cement. The teeth were then stored in artificial saliva for 24 h. The retentive strength of the crowns was determined using a specially designed Universal Testing Machine.
Statistical Analysis:
To compare the mean retentive strength between cements, ANOVA with post hoc test was applied.
Results:
Mean retentive strength for GC GOLD Label 1 group was 230.30 ± 13.46; GC FujiCEM group was 194.78 ± 13.03; and 269.25 ± 11.28 for the GC G-CEM One group. A comparison of luting cement showed the retentive strength of GC G-CEM One cement significantly higher than the rest of the two cements ( P < 0.001). The retentive strength of GC GOLD Label 1 cement was significantly higher than GC FujiCEM cement ( P < 0.001).
Conclusion:
Resin cement (GC G-CEM One) significantly improved crown retention when compared with RMGIC (GC FujiCem) and GIC (GC Gold label 1).