Related Experiment Video
Updated: Sep 18, 2025

06:51
Concurrent Electroencephalography Recording During Transcranial Alternating Current Stimulation tACS
Published on: January 22, 2016
14.7K
Characterizing low-frequency artifacts during transcranial temporal interference stimulation (tTIS).
Jill von Conta1, Florian H Kasten1,2, Branislava Ćurčić-Blake3
1Experimental Psychology Lab, Department of Psychology, European Medical School, Cluster of Excellence "Hearing4All", Carl von Ossietzky University, Oldenburg, Germany.
Neuroimage. Reports
|June 26, 2025
Summary
Transcranial temporal interference stimulation (tTIS) allows brain activity recording during stimulation. Careful inspection is needed to avoid low-frequency artifacts, enabling better understanding of tTIS mechanisms.
Area of Science:
- Neuroscience
- Neuroimaging
- Brain Stimulation
Background:
- Transcranial alternating current stimulation (tACS) modulates brain oscillations but faces challenges in simultaneous neurophysiological recording due to electromagnetic artifacts.
- Transcranial temporal interference stimulation (tTIS) offers non-invasive deep brain stimulation by interfering two high-frequency sine waves.
- Simultaneous recording of brain activity during tACS is difficult because of stimulation-induced artifacts.
Purpose of the Study:
- To investigate the feasibility of acquiring neurophysiological data during transcranial temporal interference stimulation (tTIS) without significant artifacts.
- To assess potential low-frequency artifacts in neurophysiological recordings during tTIS.
- To provide guidance for designing experimental setups for simultaneous tTIS and brain activity recording.
Main Methods:
- Application of two high-frequency sine waves to induce amplitude-modulated waveforms at a target frequency within the brain.
- Acquisition of neurophysiological data during tTIS using appropriate hardware.
- Careful inspection of recorded data for the presence of low-frequency artifacts.
Main Results:
- Neurophysiological data can be acquired during tTIS with minimal stimulation artifacts at low frequencies, provided appropriate hardware is used.
- Low-frequency artifacts may still be present in the data and require careful inspection.
- The study demonstrates the potential for simultaneous recording of brain activity and tTIS.
Conclusions:
- Transcranial temporal interference stimulation (tTIS) shows promise for simultaneous brain activity recording, overcoming limitations of tACS.
- Careful data analysis is crucial to identify and mitigate potential low-frequency artifacts.
- These findings facilitate the design of experiments to better understand tTIS mechanisms and applications.
Keywords:
ArtifactBrain oscillationsNon-invasive brain stimulation (NIBS)Transcranial temporal interference stimulation (tTIS)
