Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
A Fully-Integrated 0.068-mm3 Implantable Pressure Sensing Device With Wireless Energy Harvesting and Data Telemetry
Abstract:
This paper reports a fully-integrated sub-0.1 mm3 wireless pressure sensing device for implantable applications. The miniature device integrates a customized system-on-a-chip (SoC) and an off-the-shelf half-bridge piezoresistive pressure transducer, eliminating off-chip passive components. The SoC mainly comprises a resistance-to-time converter, a 915 MHz inductively coupled energy harvester with an on-chip coil, and a backscatter telemetry. Key innovations enabling low power, small size and high precision include: (1) A source-input common-gate amplifier based R-V converter, that reuses the transducer's bias current, (2) Advanced noise management via chopper stabilization and supply noise cancellation, and (3) A compact high-Q on-chip multi-layer stacked coil design for wireless link. The active circuits consume 9.75 $\boldsymbol{\mu}$W, fully supplied by the energy harvested wirelessly through the on-chip coil. The sensing data is transmitted wirelessly to an external recorder through the RF backscatter link. Fabricated in a 65-nm CMOS technology, the SoC occupies a die area of 400 µm × 490 µm, and the entire fully-integrated sensor has a volume of only 0.068 mm3, enabling syringe injection through a ≤0.5 mm needle. Experiments with the sensing device covered by pork have demonstrated that the device can operate at an implant depth of up to 10 mm with excellent misalignment tolerance. It offers a pressure sensing resolution of 3.1 mmHg over a relative pressure range of 0-200 mmHg and a temperature sensing resolution of 0.18°C.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...