Related Experiment Video
Updated: Jul 23, 2026

Implementing Patch Clamp and Live Fluorescence Microscopy to Monitor Functional Properties of Freshly Isolated PKD Epithelium
Published on: September 1, 2015
Incident Dark-Field (IDF) Illumination Microscopy as a Novel Tool for Real-Time, Dye-Free Parathyroid Perfusion
Ting-Chun Kuo1, Kuen-Yuan Chen1, Yu-Chang Yeh2
1Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.
Background:
Postsurgical hypoparathyroidism is a frequent complication in thyroid surgery. Visual inspection to assess parathyroid gland (PG) viability is subjective and inconsistent. Although indocyanine green (ICG) angiography can improve perfusion assessment, it introduces workflow disruptions and carries a risk of allergic reactions.
Methods:
This pilot study investigated the feasibility of incident dark-field (IDF) microscopy as a dye-free, real-time imaging method for assessing PG perfusion during thyroidectomy. Thyroidectomy patients were prospectively enrolled at a tertiary referral hospital. Parathyroid glands were visually identified and confirmed with near-infrared autofluorescence (NIRAF). Imaging was recorded using three techniques: gross inspection (GI), IDF microscopy, and ICG angiography. Perfusion status was evaluated and classified into three categories (devascularized, compromised, and well-vascularized) and reviewed by three independent, blinded observers. Statistical analyses included interobserver reliability and inter-evaluation correlation assessments.
Results:
Among 41 NIRAF-confirmed PGs, IDF microscopy demonstrated rapid assessment, requiring 2.41 ± 1.01 min per PG evaluation compared with 5.40 ± 1.53 min for ICG angiography. For PG viability evaluation, IDF showed higher correlation with ICG than GI (weighted kappa, 0.75 vs 0.60; both P < 0.001). Surpassing GI's moderate agreement (weighted kappa, 0.44-0.47; P < 0.001), IDF microscopy exhibited moderate to substantial inter-evaluation agreement (weighted kappa 0.51-0.66; P < 0.001).
Conclusions:
Incident dark-field microscopy offers a rapid, reliable, and dye-free method for real-time assessment of PG perfusion, demonstrating diagnostic performance on par with ICG angiography while providing notable workflow advantages. This technique has the potential to reduce hypoparathyroidism by enhancing PG preservation in thyroid surgery. Further studies are needed to validate these findings and refine quantification methods.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology