Related Experiment Video
Updated: Sep 16, 2025

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Palpation versus Ultrasound-Guided Dynamic Needle Tip Positioning Technique for Radial Artery Cannulation
Sujan Dhakal1,2,3, Gentle S Shrestha4,5, Ritesh Lamsal2
1Department of Anaesthesiology and Critical Care, Provincial Hospital Bhadrapur (PHB), Nepal.
Introduction:
Invasive blood pressure monitoring is the clinical reference during perioperative patient management. It is usually performed by cannulating the radial artery. Different clinical conditions make arterial cannulation difficult using the conventional palpation (CP) method. This study compares the ultrasonography (USG)-guided dynamic needle tip positioning (DNTP) technique with the CP method to assess the first-pass success rate of radial artery cannulation.
Methods:
In the operation theater of a university hospital, a total of 52 adult patients requiring arterial cannulation were randomized into two equal groups. Arterial cannulation was performed using the CP method in one group and the ultrasound-guided DNTP method in the other group. The first-pass success rate was the primary objective. The 5-minute success rate, the time required for successful cannulation, the number of skin punctures, and the number of cannulae used were also compared using the Chi-square test, an independent sample t-test, and the Mann-Whitney U test.
Results:
The first-pass success rate was significantly higher in the USG-guided DNTP method (88.5%) compared to the CP method (46.2%) (P 0.001). The overall 5-minute success rate was 96.2% in the USG-guided DNTP and 65.4% (P 0.005) in the CP method. The median time for successful cannulation was significantly lesser in the USG-guided DNTP group [44 s (IQR: 35-72)] compared to the CP group [134 s (IQR: 28-378)] (P 0.007). The mean number of skin punctures in the USG-guided DNTP group was 1.15 ± 0.46 and 2.04 ± 1.18 in the CP group (P 0.001).
Conclusion:
USG-guided DNTP method of radial artery cannulation increased the first-pass success rate.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)

