Related Experiment Video
Updated: Sep 16, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Influence of luting space settings and polymerization-induced cement shrinkage and deformation/adaptation of CAD/CAM
Leandro Maruki Pereira1, Bárbara Inácio de Melo1, Aline Aredes Bicalho2
1Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Occlusion, Fixed Prosthodontics and Dental Materials, Uberlândia, MG, Brazil.
Abstract:
This study aimed to evaluate the adaptation of CAD/CAM crowns and the impact of resin cement polymerization contraction on crown deformation under different cementation configurations. Thirty human molars were randomly divided into three groups (n = 10) to manufacture ceramic crowns with three different cementation space configurations: LD40 (40 μm), LD80 (80 μm), and LD160 (160 μm). The samples were subjected to computerized microtomography scanning for measuring internal and marginal adaptation, and internal fit was analyzed at occlusal, axial, axiogingival points. Five light-curing protocols were used to verify the wavelength spectrum peak of the curing device and the irradiance delivered using two situations: with 0 mm sensor distance and through a ceramic of differing thickness, and an external crown deformation (ECD) test. The highest statistically significant vertical fit was obtained for group LD40, independent of region. LD160 yielded the highest ECD values, independent of positioning of the buccal and distal strain gauge. The highest internal fit was observed at occlusal and axial points of the LD160 group (P<0.001), and LD80 yielded the lowest values at the axiogingival point (p = 0.003, p = 0.006). The irradiance delivered was reduced significantly upon interposition of the ceramic block to the sensor. The peak wavelength for curing was similar among the LD groups. The luting space configurations significantly influenced vertical fit and the ECD results for the CAD/CAM ceramics owing to polymerization shrinkage. Finally, variations in ceramic thickness at different sites affected both the irradiance by the curing device and ECD results.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Soundness of Cement
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Porosity in Cement Paste
The balance of water to cement in the mix is...