Related Experiment Video
Updated: Sep 8, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Secular trends in facial anthropometry among Chilean workers: Implications for ergonomic respirator design and fit
Edgardo C Silva1, Héctor Ignacio Castellucci1, Roberto Camberes1
1Centro de Estudio del Trabajo y Factores Humanos, Escuela de Kinesiología, Facultad de Medicina, Universidad de Valparaíso, Viña del Mar, Chile.
Abstract:
The ergonomic fit of respiratory protective equipment (RPE) is critical for ensuring both protection and long-term usability in occupational settings. However, most respirators are designed based on outdated or foreign anthropometric data that may not represent local populations. In Chile, as in many countries without updated national databases, this mismatch can compromise comfort, effectiveness, and user compliance. This study evaluated temporal changes in facial dimensions among Chilean workers and assessed the applicability of four widely used respirator fit test panels. Two representative datasets collected a decade apart were analyzed: Dataset A (n = 474; 2013) with manual measurements, and Dataset B (n = 2016; 2024) using 3D facial scanning. Eleven facial dimensions recommended by ISO standards were examined against the LANL half- and full-facepiece panels and the NIOSH/ISO bivariate and PCA panels. Results showed significant increases in facial size, particularly among men, and a general shift toward larger facial morphologies. The NIOSH/ISO bivariate panel provided the highest coverage, while the LANL full-facepiece panel showed the poorest fit, especially among recent male participants. Gender-based differences in fit were consistent across both datasets. These findings underscore the need for updated, population-specific anthropometric references and the ergonomic redesign of respirators and fit panels. Although centered on Chile, the study has global relevance for countries that import RPE without validating fit locally. The methodology offers a scalable approach for aligning protective equipment with evolving worker characteristics, supporting international efforts to improve comfort, safety, and usability through data-informed design. These declining match rates suggest that respirator fit panels may become increasingly outdated, potentially compromising worker safety if they are not updated to reflect current population characteristics.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...

