Abstract:
The inherent non-ideal characteristics of circuit components and inter-channel mismatch errors induce nonlinear amplitude and phase distortions in time-interleaved pipelined analog-to-digital converters (TI-pipelined ADCs), significantly degrading system performance. Limited by prior modeling, conventional digital calibration methods only correct partial errors, while machine learning (ML) approaches achieve comprehensive calibration at a high computational cost. This work proposes an ensemble calibration framework that combines polynomial modeling and ML techniques. The ensemble calibration framework employs a two-stage correction: a learned Volterra front-end performs forward mapping to compensate static baseline nonlinear distortions, while a lightweight neural network back-end implements inverse mapping to correct dynamic nonlinear distortions and inter-channel mismatch errors adaptively. Experiments conducted on TI-pipelined ADCs show improvements in both the spurious-free dynamic range (SFDR) and signal-to-noise and distortion ratio (SNDR). It is noteworthy that in two ADCs fabricated using 40 nm CMOS technology, the 12-bit, 3000 MS/s silicon-validated four-channel TI-pipelined ADC exhibits SFDR and SNDR improvements from 35.47 dB and 35.35 dB to 79.70 dB and 55.63 dB, respectively, while the 16-bit, 1000 MS/s silicon-validated four-channel TI-pipelined ADC demonstrates an enhancement from 38.62 dB and 40.21 dB to 80.90 dB and 62.43 dB, respectively. Furthermore, a comparison with related studies reveals that our method achieves comprehensive calibration performance for wide-band inputs while substantially reducing computational complexity, requiring only 4.4 K parameters and 8.57 M floating-point operations per second (FLOPs).
Related Concept Videos
Reconstruction of Signal using Interpolation
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....