Cumulative dose assessment with transformer-based deformable image registration addition for cervical cancer patients
Dongdong Zhou1, Yuheng Shao1, Fuying Wan1
1Department of Shanghai Key Laboratory of Maternal Fetal Medicine, Shanghai Institute of Maternal-Fetal Medicine and Gynecologic Oncology, Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji University, Shanghai, China.
Purpose:
Based on the combination mode of internal and external radiotherapy for cervical cancer, this study aimed to investigate an accurate transformer-based deformable image registration (DIR) method for cumulative dose assessment.
Methods And Materials:
According to a retrospective analysis conducted on 180 patients with cervical cancer who underwent intracavitary brachytherapy (ICBT) and external beam radiation therapy (EBRT), this study proposed a mix-transformer structure-based deformable image registration (MTDIR) network for registering CT scans of ICBT and EBRT, followed by dose accumulation and assessment. The mean dice similarity coefficient (DSC) and Hausdorff distance (HD) of the rectum and bladder were computed to compare the performance of MTDIR with that of the state-of-the-art VoxelMorph method and the DIR method provided by velocity. Additionally, the cumulative dose of the bladder and rectum from four methods was calculated: direct DVH parameter addition (DA), DIR-based dose addition provided by Velocity (VA), VoxelMorph-based dose addition (VoA), and MTDIR-based dose addition (MA).
Results:
The mean DSC values of MTDIR, VoxelMorph, and Velocity for the bladder were 0.78, 0.75, and 0.72 for the registration between CT scans of EBRT and the last ICBT, respectively. The mean DSC values of the rectum were also equal to 0.58, 0.56, and 0.52. The mean HDmean values of MTDIR, VoxelMorph, and Velocity for the bladder were 4.81, 5.16, and 5.43, and the mean HDmean values of the rectum were 5.41, 5.81, and 6.93, respectively. For the registration between CT scans of ICBT, the mean DSC values of MTDIR, VoxelMorph, and Velocity for the bladder were obtained 0.82, 0.80, and 0.77, and the mean DSC values for the rectum were equal to 0.70, 0.68, and 0.63, respectively. The mean HDmean values of MTDIR, VoxelMorph, and Velocity for the bladder were 4.22, 4.58, and 4.79, and the mean HDmean values of the rectum were obtained 4.86, 5.17, and 5.64, respectively. The results generally suggested that MTDIR outperformed VoxelMorph and Velocity.
Conclusions:
The study findings demonstrated that the model developed based on parameters obtained from the proposed method exhibited higher registration accuracy.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dosage Regimen Designs: Nomograms and Tabulations
Drug Accumulation During Multiple Dosing: Repetitive IV Injections