Summary
A new lipid ratio plot method accurately assesses low-density lipoprotein cholesterol (LDL-C) test results against the reference method. This graphical approach helps clinical labs evaluate LDL-C assay accuracy, especially when the reference method is unavailable.
Area of Science:
- Clinical Chemistry
- Biomarker Measurement
- Laboratory Diagnostics
Background:
- Beta-quantification (BQ) is the gold standard for low-density lipoprotein cholesterol (LDL-C) measurement but is not widely accessible.
- Clinical laboratories face challenges in verifying the accuracy of routine LDL-C assays due to the limited availability of the BQ reference method.
Purpose of the Study:
- To develop and validate an indirect graphical method for comparing LDL-C results from various assays to the BQ reference method.
- To establish a practical tool for laboratories to assess LDL-C assay accuracy without direct access to BQ.
Main Methods:
- Utilized large datasets (n=39,969 and n=17,825) of lipid panel results from Mayo Medical Laboratories and the National Institutes of Health.
- Developed a 'lipid ratio plot' by plotting LDL-C/non-high-density lipoprotein cholesterol (nonHDL-C) against the square root of the triglyceride (TG)/nonHDL-C ratio.
- Determined the minimum sample size (n=80) required for reliable slope and intercept calculations with a 7.5% coefficient of variation.
Main Results:
- The lipid ratio plot demonstrated excellent agreement with the BQ method for LDL-C calculated using Sampson-NIH and enhanced Sampson-NIH equations.
- The Martin-Hopkins and Friedewald equations showed increasing biases with hypertriglyceridemia, exceeding acceptable limits.
- Direct assays from Roche exhibited a fixed positive bias, while Beckman assays showed a proportional positive bias that increased with triglyceride levels.
Conclusions:
- The lipid ratio plot is a straightforward and effective graphical tool for clinical laboratories.