Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
Evaluating the Accuracy of Low-Cost Wearable Sensors for Healthcare Monitoring
Tatiana Pereira Filgueiras1, Pedro Bertemes-Filho1, Fabrício Noveletto1
1Department of Electrical Engineering, Santa Catarina State University, Joinville 89219-710, SC, Brazil.
Abstract:
This study evaluates the accuracy of a low-cost wearable system for the continuous monitoring of vital signs, including heart rate, blood oxygen saturation (SpO2), blood pressure trend (BPT), and body temperature. The prototype was built using the nRF52840 microcontroller, which integrates photoplethysmography and infrared sensors. The heart rate and SpO2 data were collected under three body positions (Rest, Sitting, and Standing), while all measurements were performed using both anatomical configurations: BPT-Finger and BPT-Earlobe. Results were compared against validated commercial devices: UT-100 for heart rate and SpO2, G-TECH LA800 for blood pressure, and G-TECH THGTSC3 for body temperature. Ten participants were monitored over a ten-day period. Bland-Altman analysis revealed clinically acceptable agreement thresholds of ±5 mmHg for blood pressure, ±5-10 bpm for heart rate, ±4% for SpO2, and ±0.5 °C for temperature. Both wearable configurations demonstrated clinically acceptable agreement across all vital signs. The BPT-Earlobe configuration exhibited superior stability and lower variability in the Rest and Sitting positions, likely due to reduced motion artifacts. Conversely, the BPT-Finger configuration showed higher SpO2 accuracy in the Standing position, with narrower limits of agreement. These findings highlight the importance of sensor placement in maintaining measurement consistency across physiological conditions. With an estimated cost of only ~USD 130-compared to ~USD 590 for the commercial alternatives-the proposed system presents a cost-effective, scalable, and accessible solution for decentralized health monitoring, particularly in underserved or remote environments.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.