Virtual Non-Contrast Reconstructions Derived from Dual-Energy CTA Scans in Peripheral Arterial Disease: Comparison
Fanni Éva Szablics1, Ákos Bérczi1, Judit Csőre1
1Department of Interventional Radiology, Heart and Vascular Center, Semmelweis University, Városmajor utca 68, 1122 Budapest, Hungary.
None:
Background/Objectives: Virtual non-contrast (VNC) images derived from dual-energy CTA (DE-CTA) could potentially replace true non-contrast (TNC) scans while reducing radiation exposure. This study evaluated the image quality of VNC compared to TNC for assessing native arteries and bypass grafts in patients with peripheral arterial disease (PAD). Methods: We retrospectively analyzed 175 patients (111 men, 64 women, mean age: 69.3 ± 9.5 years) with PAD who underwent lower extremity DE-CTA. Mean attenuation and image noise values of TNC and VNC images were measured in native arteries and bypass grafts at six arterial levels, from the aorta to the popliteal arteries, using circular regions of interest (ROI). Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Three independent radiologists evaluated the subjective image quality of VNC images compared to baseline TNC scans for overall quality (4-point Likert scale), and for residual contrast medium (CM), calcium subtractions, and bypass graft visualization (3-point Likert scales). Radiation dose parameters (DLP, CTDIvol) were recorded to estimate effective dose values (ED) and the potential radiation dose reduction. Differences between TNC and VNC measurements and radiation dose parameters were compared using a paired t-test. Interobserver agreement was assessed with Gwet's AC2. Results: VNC attenuation and noise values were significantly lower across all native arterial levels (p < 0.05, mean difference: 4.7 HU-10.8 HU) and generally lower at all bypass regions (mean difference: 2.2 HU-13.8 HU). Mean image quality scores were 3.03 (overall quality), 2.99 (residual contrast), 2.04 (subtracted calcifications), and 3.0 (graft visualization). Inter-reader agreement was excellent for each assessment (AC2 ≥ 0.81). The estimated radiation dose reduction was 36.8% (p < 0.0001). Conclusions: VNC reconstructions demonstrated comparable image quality to TNC in a PAD assessment and offer substantial radiation dose reduction, supporting their potential as a promising alternative in clinical practice. Further prospective studies and optimization of reconstruction algorithms remain essential to confirm diagnostic accuracy and address remaining technical limitations.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies VII: Vascular Imaging
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...