Related Experiment Video
Updated: Jun 17, 2026

Laparoscopic Non-Mesh Cerclage Pectopexy for Pelvic Organ Prolapse
Published on: September 13, 2022
Metal-Free Cerclage Method of Arthroscopic Latarjet Using a Printed Poly Lactic Acid Coracoid Protector to Prevent
Sujit Jos1, Rakshit J1, Vyas Vijayakumar1
1Institute of Advanced Orthopedics, MOSC Medical College Hospital, Kolenchery, Kochi, Kerala, India.
Abstract:
Although the arthroscopic Latarjet procedure has evolved as the most reliable bony sling procedure for shoulder instability with bone loss, the soft cancellous nature of the coracoid makes the FiberTape option for metal-free fixation difficult because of cheese wiring and cutting into the coracoid when the tape is tensioned. Hence, long titanium screws or titanium buttons are used to fix the coracoid in all existing methods for the Latarjet procedure. Rigid and metal-based methods can cause abrasion of the bony moving surfaces coated with cartilage and can cause wear to contact areas, especially when osteolysis occurs during remodeling of the coracoid bone. We describe an absorbable poly lactic acid 3-dimensional printed coracoid protector (which we call the SJ Buckler) to protect the coracoid process resting on its anterior surface and prevent cut through, with laboratory-verified strength to withstand greater than 120 N. This allows us to perform metal-free fixation of the coracoid in the Latarjet procedure, which can be performed arthroscopically or open, where the coracoid tensioning can be done without fear of cut-through. The poly lactic acid material is absorbable and will integrate to bone or disintegrate after the purpose of bony union to glenoid has been achieved.
More Related Videos
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Holter Monitor: 24-Hour Monitoring
Cardiac Catheterization IV: Nursing Management

